Installation:1. Line up the edges as shown (fi g. 2). 2. Slide the battery into the Blower.3. Make sure there is an audible click as the battery is sec

Página 3 - Table Of Contents

Filter Installation:1. Remove any Filter packaging from the Filter.2. Remove the Filter Cap from the Blower (fi g. 3). 3. Remove the old fi lter (if ins

Página 4

#12.3 Blower1. Install the Breathing Tube into the Blower as shown (fi g. 6). 2. Operate the Blower (fi g. 7). #2fairAudible Alarm (short beep) &

Página 5 - 1.0 General Information

2.4 Headtop1. Install and Lock the Breathing Tube into the Airduct on the Headtop (fi g. 8) 2. (Welding Helmet headtops only) Adjust the headgear front

Página 6 - 1.2 Operating Principals

Hard Hat headtops only:1. Install accessory slot plug (straight bill hard hat only), if not already installed or optional accessory. (fi g. 9) 2. Remov

Página 7

2.6 Pre-Operational InspectionCheck the following before donning your Clean Air FlowTM PAPR system. If any of the following are not in compliance refe

Página 8

Failure to properly connect the Breathing Tube to the Helmet Assembly and to confi rm airfl ow through the system to the Breathing Zone could lead to co

Página 9 - 2.1 Battery

2.8 TroubleshootingIf, at any time during operation, you detect an odor or taste of gas or vapor, or if you feel eye or throat irritation, you must

Página 10 - 2.2 Filters

3.0 Maintenance and Storage3.2 Cleaning1. ALWAYS INSPECT YOUR CLEAN AIR FLOWTM PAPR system after cleaning. Clean the external surfaces of the Clean Ai

Página 11 - Filter Installation:

Cleaning Continued...2. Detach the breathing tube from the blower unit and the helmet assembly (see section 4.3 & 4.4), and wipe the connection si

Página 12 - 2.3 Blower

CAUTIONWARNINGDefi nition of Safety Signal Words per ANSI Z 535.4Indicates a potentially hazardous situation which, if not avoided, could result in dea

Página 13 - 2.4 Headtop

3.4 Storage• Before storing the Clean Air FlowTM system, it should be thoroughly dry. Do Not Keep used fi lter in the same enclosed storage space a

Página 14 - 2.5 Waist Belt

The Blower and Battery Units are supplied as seal-testedunits. Any attempt to open or repair the unit will result inthe termination of the limited w

Página 15 - 2.7 Donning

Faceseal Replacement: Viper continued...Installation: 1. Line up the bottom seam of the Faceseal to the centerline of the Helmet (fi g. 16)2. Attach th

Página 16 - CAUTION:

5. Thread the Airduct over the Headgear and attach to the front and top of the Headgear with the Velcro strips as shown (fi g. 19). VelcroVisor Rep

Página 17 - 2.8 Troubleshooting

4. Pull the Faceseal off the Hard Hat.Installation: (Procedure is same for reverse bill hard hat assembly with exception of faceseal visor orienated o

Página 18 - 3.2 Cleaning

Faceseal Replacement: Vision AirDuct Headgear Assemblyp Welding Helmet ShellFace Seal of Corresponding Headtop (CA-COL-XX) Airduct Headgear Assembly

Página 19

4.6 Waist BeltRemoval:1. Remove the Waist Belt from the clip.2. Unthread the Waist Belt Strap from the Blower.Installation: 1. Thread the Waist Belt S

Página 20 - Direction

4.7 Airduct Headgear Assembly Replacement Welding Helmet ShellAirduct Headgear Assembly (CA-HGA-01) Face Seal (CA-COL-XX)Knob Pivot StopBoltStep

Página 21 - 4.5 Faceseal

4.8 Auto-Darkening Lens ReplacementRefer to ArcOne’s Auto-Darkening Welding Helmets- “User Instruction Manual” which is enclosed for information on th

Página 22 - Figure 18

5.1.3 Helmet Assembly: Part No. Description CA-HGA-01 Ratchet Headgear - AirDuct Assembly 01-HGA Ratchet Headgear Fastener Assembly

Página 23 - Hard Hat

Table Of Contents1.0 General Information1.1 Introduction1.2 Operating Principles1.3 Respirator Approvals & Limitations1.4 Helmet & Weldin

Página 24 - Faceseal

5.2 Technical Specifi cations Compact Air PAPR SystemBlo

Página 25 - Figure 26

Note: NIOSH Approval covers complete respirator systems only, as confi gured from approved components as referenced on the NIOSH approval label for t

Página 26 - Waist Belt

ArcOne warrants the complete Clean Air FlowTM PAPR Systems for one (1) year from the date of purchase against all manufacturing defects resulting fr

Página 27 - Figure 30

4.6 Servicing Your Clean Air FlowTM PAPR SystemPlease contact ArcOne directly for any questions regarding the function of your Clean Air FlowTM PAPR

Página 28 - 5.0 Customer Information

Please Contact: ARCONE Service Center,Telephone: 800-223-4685, Fax: 508-884-9666OrVisit Our Website www.arc1weldsafe.comA Division of A. C. E. Inte

Página 29

Please Contact: ARCONE Service Center,Telephone: 800-223-4685, Fax: 508-884-9666OrVisit Our Website www.arc1weldsafe.comA Division of A. C. E. Inte

Página 30 -

Please Contact: ARCONE Service Center,Telephone: 800-223-4685, Fax: 508-884-9666OrVisit Our Website www.arc1weldsafe.comA Division of A. C. E. Inte

Página 31

byA complete Clean Air FlowTM System Includes:• A Choice of Lightweight and Durable Nylon Vision or Viper Welding Helmet or a Hard Hat Visor combin

Página 32 - 5.3 Warranty

1.0 General Information1.1 IntroductionCongratulations! You have purchased the ultimate in comfortable welding powered respiratory protection equ

Página 33 - ArcOne Service Center

This Clean Air FlowTM system is used in a welding environment where protection is required against harmful particles and mist. The Clean Air FlowTM ,

Página 34 - www.arc1weldsafe.com

1.3 Respirator Approvals & LimitationsThe Clean Air FlowTM System as described in this instruction manual has been approved by the following agen

Página 35

Cautions and Limitations (refer to the enclosed Approval Labels)• Not for use in atmospheres containing less that 19.5 percent oxygen.• Not for use in

Página 36

#11.4 Helmet and Auto-Darkening Lens ApprovalsThe ArcOne helmet, consisting of the Vision and Viper series and the full family of ArcOne’s Auto-Darke